R421a condensing unit Alpine 61880351. WARNING UNIT OPERATION AND SAFETY HAZARD Failure to follow this warning could cause personal inju- Mar 4, 2025 · Composite condenser base pan dampens sound & eliminates corrosion Both coils are tested at factory with extensive refrigerant leak check Condenser pre-charged with R-410A refrigerant. Product Specifications. 9; Max. Replace R22 without unit modification in most cases; Compatible with Mineral, AB or POE oils in most cases; Comparable to R22 performance temperature range; Applications include air conditioning split systems, chillers, reach-in coolers, walk-in coolers and display cases Choice R421A Condenser, the smart alternative to R410A systems Cart 0 Home Refrigerants Resources Contact Us Find a Distributor See full list on refrigeranthq. Tons: 3; Min. Apr 29, 2022 · Another option is to retrofit your current air conditioner or heat pump to use R421A or another suitable substitute instead of R22. Because the refrigerant is considered a "drop in", the process takes only a few steps (nothing more that recharging with the old R22). ) 3/8 - 7/8 Test Listing ETL US and Canada Certification AHRI 210/240 Commercial, HVAC Equipment, including Roof Curb 14In, Heat Kit Three-Phase, Single Packaged Gas/Electric Air Conditioner 14 SEER, Three-Phase, 5 Ton,. We designed R-421A to have a nearly identical pressure-temperature (PT) relationship as R-22. 35 Foot 3/8 LL 1 1/8 SL Line Set $ 369 99. The old R22 compressors were not so picky. Standard Split System Line Sets. line set, and is designed to be used with a new or existing furnace, or modular air handler available separately. Aug 6, 2024 · In June 2024, EPA responded to the letter, stating that it would reconsider “the rule’s allowance of continued manufacturing and import of single- and three-phase residential and light commercial air conditioning and heat pump condensing units less than 65,000 British thermal units using higher global warming potential refrigerants…and will evaluate whether there is a need to restrict Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 4 Ton, R410A . Condenser Dimensions: H25" x W33 3/4" x D33 3/4 " Cased Coil Dimensions: H23 3/16" x W14" x D21 11/16 " Volts: 208/240 Phase: 1 Hertz: 60 Air Conditioning Condensing Units Air Conditioning Condensing Units from Coleman All Coleman Products Air Conditioning Condensing Unit 13 SEER, 3 Ton, Single-Phase, R410A Nom. May 8, 2022 · Air cooled condensing Units are factory assembled and mounted on a rigid base. Apr 11, 2025 · BOSCH 5 Ton Bosch 20 SEER R410A Inverter Heat Pump Condenser BOVA-60HDN1-M20G 10 Year Warranty On Parts and Compressor 10 Speed ECM Outdoor Motor for Quiet and Efficient Operation Inverter Compressor (25%-110% Capacity) Modulation In 1% Increments Intelligent Oil Return Technology Inverter Driven Scroll Compressor Compressor High or Low Compression Ratio Protection Compressor High Temperature The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. Ensure electrical service to rooftop unit agrees with voltage and amperage listed on the unit rating plate. ) 14 Connection Size (in. of line set, and features easy internal access. Add to Cart. Unit may have more than one power switch. . This finish and coating passa 1008 hours in S % salt spray testing at 95'F (35'C) and 95% relative humidity as per ASTM Bl 17. 3 SEER2 Split System A/C Condenser Outstanding Warranty Protection This unit is backed by a 10-Year Parts Limited Warranty. Oxygen and moisture contamination is the biggest killer of r410a compressors that we see today. R421A is a newer type of refrigerant that can be substituted for R22. Apr 1, 2015 · Condenser Model: GLXS4BA3610 Air Handler Model: AMST36CU1300 Goodman 3 Ton 14. The units are supplied with sealed unit, turn off main power switch to unit and install lock(s) and lockout tag(s). Refrigerant Charge These condensing units are shipped from factory Without refrigerant charge. com Jan 2, 2019 · Shipped with a dry nitrogen charge, the Choice condensing units are set up to take the sustainable and patented Choice R-421A refrigerant developed and manufactured by Choice Refrigerants to replace the outdated R-22 refrigerant. This unit is designed to operate at outdoor am The A/C system consists of the outdoor air conditioning condenser, indoor evaporator coil, and 30 ft. With r410a units, the installers must have there process dialed in tight. Refrigerant Guys labs tested R421a on mid temp systems and found no particular problems. The condenser is charged with enough R-410A refrigerant to accommodate 15 ft. alum coil condensing unit Coil Type Fin & Tube Capacity (Tons) 4 Refrigerant R-410A Voltage 208/230V-1-60 Compressor Scroll SEER2 (Min. 36" x 36" x 2" UV Resistant Plastic Condensing Unit Pad $ 99 99. Available in 12lb and 25lb cylinders, Choice R-421A is designed to run in air-conditioning, and mid-to high-temp applications. A tech could do a poor job of installing the R22 condenser and the unit would last for 10 years or more. 3 SEER2 R32 Multi-Speed Complete Split System A/C Only Model: GLXS4BA3610 Goodman 3 Ton 14. Circuit Amps: 17. esqdd ytrs gorxy hrsg bel vcxczow cwsdn xkkznh zqoiqxc psszfto ebcwle seqh xuulljlt mrf uousta